Battery replacement – AMX MVP-5100 User Manual

Page 158

Advertising
background image

Battery Life and Replacement

150

MVP-5100/5150 Modero Viewpoint Touch Panels

Battery Replacement

The touch panel's battery is intended to last the life of the device, but it may be upgraded for additional
run time. In cases where the battery has reached its effective end of life, it may be replaced with the
MVP-BP-52 Battery Pack Kit (FG5966-20). To replace the battery:

1.

Shut down the device.

2.

Place the device face-down and remove the five screws from the back of the device.

Two of the screws are at each of the upper corners of the device, underneath screw covers.
Remove the screw covers to access the screws by prying them out of their slots with a
screwdriver or similar tool.

Reach the remaining screws by removing the long screw cover at the bottom of the device.

3.

Carefully remove the back of the device, making sure not to dislodge the IR emitter panel.

4.

Disconnect and remove the old battery from the female connector (FIG. 88).

5.

Connect the new battery, making sure to seat fully the battery’s female connector to the male
connector in the device. Use a clean, nonconductive stick or probe to seat the connectors.

6.

Install the new battery, making sure that the label faces outward and the battery connector wiring
runs to the left (FIG. 88). Make sure that the excess battery wiring fits in the space to the bottom left
of the battery.

7.

Reattach the back of the device.

8.

Insert the five screws and replace the screw covers, using the replacement screw covers included in
the Battery Pack Kit.

9.

Restart the device to confirm that the new battery is functioning correctly.

FIG. 88

Battery installation and connection diagram

Battery

Female connector

Excess battery wiring

Advertising
This manual is related to the following products: