to zero and an audio signal will sound at the end
of the steaming cycle.

6. Remove steamed product.

Programming

CYC (Total Cycle Time) refers to the total amount of
cooking time set for the product.

SHO (Shot Interval Time) is the time set between
shots of steam during a complete cycle.

H

2

O setting (Steam Shot Time) is used to adjust the

water volume during each pump/solenoid operation, or
“shot” of steam.

The amount of steam produced by your Miracle
Steamer depends on the amount of water sprayed onto
the steam generator.

Flooding of the generator may occur if the H

2

O ) set-

ting is set too high. To prevent this from occurring, the
Shot Interval Time (SHO) may be increased to allow
more time for generator recovery. Adjustments should
be made to both values to determine the optimum set-
tings for your cooking needs.

To program the control, refer to Figure 6 and use the
following procedure in sequence:

1. Turn the rocker switch (power on/off) to ON. The

display will show the factory programmed
(default) Total Cycle Time in minutes/seconds
(Item A, Figure 6).

2. Depress the program button to change the control

from OPERATION to PROGRAM mode.

3. To change the Total Cycle Time factory settings

(default), use the UP or DOWN arrow buttons to
change the Total Cycle time in minutes (Item B,
Figure 6).

4. Depress the program button again, and use the

UP or DOWN arrow buttons to change the Total
Cycle Time in seconds (Item C, Figure 6).

5. To change the SHO factory settings (default),

make sure the control is in PROGRAM mode,
then depress the two arrow buttons simultane-
ously. SHO will be displayed (Item D, Figure 6).

MIRACLE STEAMER

9

P/N 1010699 Rev. B

A.J. Antunes & Co.

IMPORTANT: Your 208V and/or 220-240V Miracle
Steamer is factory programmed for the following set-
tings:

Total Cycle Time (CYC) = 15 minutes
(Range: 3 secs to 99 mins 59 secs)

Shot Interval Time (SHO) = 20 seconds
(Range: 3 secs to 5 mins 59 secs)

Steam Shot Time (H

2

O) =

MS-150/155/355 - (1_00) or 1.00 sec
MS-250/255 - (0_70) or 0.70 sec
(Range: 0.10 sec to 2.50 sec)

This converts approximately 3/4 oz. (25 milliliters) of
water to steam every 20 seconds for a 15 minute cook-
ing cycle. To change any of these settings see

PRO-

GRAMMING on this page.

IMPORTANT: Your 120V Miracle Steamer is factory
programmed for the following settings:

Total Cycle Time (CYC) = 2 minutes
(Range: 3 secs to 99 mins 59 secs)

Shot Interval Time (SHO) = 20 seconds
(Range: 3 secs to 5 mins 59 secs)

Steam Shot Time (H

2

O) =

MS-250/255 - (0_40) or 0.40 sec
(Range: 0.10 sec to 2.50 sec)

Operating Instructions

1. Turn the rocker switch (power on/off) to ON (Figure 5).

2. Allow the unit to preheat for approximately 20-30

minutes.

NOTE: Do not push the operate button during warm-
up time. The flashing green ready light indicates the
unit is NOT up to temperature.

NOTE: The flashing green ready light will become
STEADY when the unit is up to temperature.

3. Pull out the spatula and place the product to be

steamed onto the spatula.

4. Push the spatula fully into the steamer.

5. Single Shot: Press and release the operate but-

ton, wait 20 seconds for the steam to penetrate
the product.

Timed Cycle: Press the start/stop button to begin
the steaming cycle. The display will count down

WARNING

To avoid injury, be careful when pulling spatula
out from unit. Be sure to allow steam to escape
before putting hands or face over the steamer.