Figure 9. Water Filters–MS-150/155

Top Water Filter

Bottom Water Filter

Water Filters–Models MS-150/155

To prevent solids or food products from entering the
water pump, the unit uses two water filters (Figure 9).
Inspect and clean (if necessary) these filters monthly
using the following procedure:

1. Turn the rocker switch (power on/off) to OFF.

Unplug the power cord and allow the unit to cool
down before proceeding.

2. Remove access cover and tank assembly.

3. Drain water from access cover/tank assembly by

sliding tank assembly cover open, tip assembly
and pour water into a container or sink.

4. Remove top filter located inside the tank by

pulling it out (Figure 9).

5. Remove bottom filter located in water tank outlet

tube by disconnecting the hose from the outlet
and removing filter (Figure 9).

6. Clean filters by running them under tap water.

Replace them if they are torn or damaged.

7. Install bottom filter inside the water outlet tube.

Install outlet hose and clamp.

8. Install top filter into water outlet tube inside the

tank.

9. Install access cover and tank assembly.

10. Fill water tank and test unit.

NOTE: The MS-355 does not use a water filter.

Direct water hook-up Units (MS-250/255)

Use of the optional water regulator kit, part no.
7000235, is recommended (see page 25).