CS2000-OTP

22

DS758F2

6. PARAMETER DESCRIPTIONS

As mentioned in

Section 5.1 on page 11

, there are two different kinds of parameter configuration sets, Modal and

Global. These configuration sets, shown in

Figure 17

, can be programmed in the field using the CDK2000 or pre-

programmed at the factory. Please see

“Programming Information” on page 27

for more details.

Figure 17. Parameter Configuration Sets

6.1

Modal Configuration Sets

There are four instances of each of these configuration parameters. Selection between the four stored sets
is made using the M[1:0] pins.

6.1.1

R-Mod Selection (RModSel[1:0])

Selects the R-Mod value, which is used as a factor in determining the PLL’s Fractional N.

Note:

This parameter does not take affect unless M2 pin is high and the M2Config[2:0] global param-

eter is set to ‘011’.

RModSel[1:0]

R-Mod Selection

00

Right-shift R-value by 1 (÷ 2).

01

Right-shift R-value by 2 (÷ 4).

10

Right-shift R-value by 3 (÷ 8).

11

Right-shift R-value by 4 (÷ 16).

Application:

“Ratio Modifier (R-Mod)” on page 15

M[1:0] pins

Modal Configuration Set #0

RModSel[1:0]

LockClk[1:0]

FracNSrc

AuxOutSrc[1:0]

Modal Configuration Set #1

Ratio 1

RModSel[1:0]

LockClk[1:0]

FracNSrc

AuxOutSrc[1:0]

Modal Configuration Set #2

Ratio 2

RModSel[1:0]

LockClk[1:0]

FracNSrc

AuxOutSrc[1:0]

Modal Configuration Set #3

Ratio 3

RModSel[1:0]

LockClk[1:0]

FracNSrc

AuxOutSrc[1:0]

00

01

10

11

Global Configuration Set

RefClkDiv[1:0]

ClkOutUnl

AuxLockCfg

LFRatioCfg

M2Config[2:0]

Ratio 0

Di

git

a

l/

P

L

L

C

o

re

ClkIn_BW[2:0]