STOPPER INSTALLATION PROCEDURE

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.

To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the

rear of the

Sink and the American Standard logo is facing

front. Rotate

Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.

Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.

To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the

front of the

Sink and the American Standard logo is facing

rear. Rotate Stopper

slightly if necessary so that the Stopper slides all the way down.

Fig. H.

Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable

.

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).

Unlocked Mode

LOOP TOWARD
FRONT OF SINK

180˚

LOGO

DRAIN

Fig. H.

Locked Mode

(Vandal Proof)

LOGO

DRAIN

Fig. G.

LOOP TOWARD
REAR OF SINK

7

Fig. J.

Fig. K.

INSTALL
CAM CAP

CAM

INSTALL CAM

Advertising