TROUBLESHOOTING & OPERATION NOTES:

1) If the Display ever becomes locked showing "Out2", please recalibrate the scale as outlined in the
manual

2) If the Display ever becomes locked on 1HHH, LLLL or EEEE, this indicates that the scale was shocked,
dropped or otherwise damaged and the delicate weighing sensors have been damaged. You can try
recalibrating the scale (If the sensor has not been hurt too badly it will work again after recalibration).
Otherwise you will have to follow the warranty instructions that came with your scale.

3) If the display becomes locked on 8888, this often indicates low batteries. However sometimes it also
may indicate a serious zero mark error. This means when you turn the scale on, it can't determine what
zero is (a slight zero mark error will cause situation #1 above) Thus, if new batteries do not fix this error
the scale will have to be sent to us for replacement under our Lifetime/30 year warranty program.

4) If the display shows UNST, this means the scale is not stable. Please try operating the scale on a more
stable surface and be sure nothing is on the tray or stuck under the tray when you turn it on. If this
situation persists, it may be an indication of fatal load cell damage. Try calibrating the scale - if this does
not work please follow the warranty instructions.

Although the TRITON is designed to be extremely durable, It’s important that you never overload or
drop/shock the scale. Scales are delicate instruments and unlike Cellular phones, scales have delicate
sensors that determine how much an item weighs. If you drop or shock your scale, these sensors "feel"
the shock and are sometimes destroyed. This happens with all digital scales. We design our scales to be
as resistant to shock or drops as possible, however there is no way for us to protect 100% against load
cell or sensor damage. A well-treated scale will provide years of reliable and accurate weighing.
However an abused scale will only work until it’s sensors are damaged.

PROPER OPERATION AND ENVIRONMENT

If the display ever becomes locked on Out2, please recalibrate the scale as outlined below.

Always use a gentle touch on the buttons - don't press hard!

Avoid lengthy exposure to extreme heat or cold, your scale works best when operated at normal
room temperature. Always allow the unit to acclimate to a normal room temperature for at
least one hour before use.

Allow sufficient warm up time. Turn the scale On and wait several seconds to give the internal
components a chance to stabilize before weighing.