7) Do not leave anything on the scale when not in use.
8) If the scale is excessively cold or hot, allow the scale to warm up to
normal room temperature for at least 1 hour prior to use.
9) Do not operate a cell phone or cordless phone within 10 feet
of the scale**** It may temporarily cause the scale to malfunction
10) If the scale shows the Low Battery animation or if the battery symbol remains on during use, please
replace the batteries.
11) In the unlikely event that the scale permanently “locks up” or shows
ERR, visit

www.FLIPSCALE.com

for Advanced Troubleshooting.

12) In the unlikely event your scale should require recalibration
please refer to the calibration instructions in this manual.
13) Please keep your scale in it’s protective pouch when not in use.

INSTRUCTION MANUAL
1. Do not put anything on the scale tray before you turn it on.
2. Turn the scale on by pressing ON. The Power On Animation will display, then the display will show
0.0g.
3. Always allow the scale to warm up for several seconds before weighing for accuracy & stability.
4. Place the item to be weighed on the center of the silver platform and read the value on the display.
5. TARE Function: If you need to weigh loose items or anything in a container or tray you should: 1) Turn
the scale On. 2) Place the empty container or tray on the platform. 3) Press the TARE button. 4) Place
the items to be weighed into the container / tray. 5) The exact weight of the items will show. (use your
tweezers to handle all gems)
6. The scale has an Auto-Off feature that turns off the scale after lapses of non-activity. If the scale is in a
room with wind or air movement, it may sense the pressure of the air and not auto-off. In this case
simply press off to turn the scale off manually.
7. MODE Function: This scale has the ability to weigh in grams, ounces, pennyweights, carats or troy
ounces. The selection is done by simply pressing the MODE key once the scale is on (Look for the g, oz,
dwt, ct or ozt on the top of the display).
8. Temperature: The recommended operating temperature is 64-82F (16-25C)Please only operate the
scale at recommended temperatures.
CAPACITY OF SCALE: 200G ACCURACY + / - 0.1G

CALIBRATION INSTRUCTIONS
THIS SCALE IS ACCURATE WITHIN 0.1g, only calibrate if your readings are inaccurate beyond 0.1g. Allow
your scale to warm up for several seconds before calibration. Always move your hands very gently
during calibration as to not cause vibrations or air movement.

Simple calibration
1. Turn on the scale and wait for “0.0g” to appear
2. Put a 100g standard weight on the platform and wait until it is stable.
3. Press and hold the MODE button for several seconds until the display flashes 100.0 twice.
Calibration is complete, release the MODE button and remove the weight from the platform.