4. Configuration

4.1 Configuration Menus

1A model

Application

(section 4.2)

Default mode &

Output 1 type

(section 4.3.1)

NSB value

(section 5.6)

Output 1

min. opening

(section 4.3.2)

Maximum

setpoint

(section 4.6)

Minimum

setpoint

(section 4.6)

0 Internal sensor

0 Cool / 0-10V

1 1°C (2°F)

0 0%

Can be set
between 35°C
(95°F) and
’’minimum
setpoint + 1’’

Default value
is 35°C (95°F)

Can be set
between 10°C
(50°F) and
’’maximum
setpoint - 1’’

Default value
is 10°C (50°F)

1 Room

1 Heat / 0-10 V

2 2°C (4°F)

1 10%

2 Return

2 Cool / 2-10 V

3 3°C (6°F)

2 20%

3 Supply

3 Heat / 2-10 V

4 4°C (8°F)

3 30%

4 Auto changeover

5 5°C (10°F)

4 40%

5 Limited cooling

6 6°C (12°F)

5 50%

7 7°C (14°F)
8 8°C (16°F)
9 9°C (18°F)

1F model

Application

(section 4.2)

Default mode

(section 4.3.1)

NSB value

(section 5.6)

Output 1

min. opening

(section 4.3.2)

Output 1

opening time

(section 4.3.3)

Maximum

setpoint

(section 4.6)

Minimum

setpoint

(section 4.6)

0 Internal sensor

0 Cool

1 1°C (2°F)

0 0%

0 80

Can be set
between 35°C
(95°F) and
’’minimum
setpoint + 1’’

Default value
is 35°C (95°F)

Can be set
between 10°C
(50°F) and
’’maximum
setpoint - 1’’

Default value
is 10°C (50°F)

1 Room

1 Heat

2 2°C (4°F)

1 10%

1 90

2 Return

3 3°C (6°F)

2 20%

2 100

3 Supply

4 4°C (8°F)

3 30%

3 110

4 Auto changeover

5 5°C (10°F)

4 40%

4 120

5 Limited cooling

6 6°C (12°F)

5 50%

5 130

7 7°C (14°F)

6 140

8 8°C (16°F)

7 150

9 9°C (18°F)

8 160

1A2T model

Application

(section 4.2)

Default mode &

Output 1 type

(section 4.3.1)

Output 2 type

a

(section 4.4)

Output 3 type

(section 4.5)

Output 3

activation

(section 4.5)

NSB value

(section 5.6)

Output 1

min. opening

(section 4.3.2)

Maximum

setpoint

(section 4.6)

Minimum

setpoint

(section 4.6)

0 Internal sensor

0 Cool / 0-10V

0 Not used

0 Not used

0 100%

1 1°C (2°F)

0 0%

Can be set
between 35°C
(95°F) and
’’minimum
setpoint + 1’’

Default value
is 35°C (95°F)

Can be set
between 10°C
(50°F) and
’’maximum
setpoint - 1’’

Default value
is 10°C (50°F)

1 Room

1 Heat / 0-10 V

1 SSR 24 VAC

1 SSR 24 VAC

1 10%

2 2°C (4°F)

1 10%

2 Return

2 Cool / 2-10 V

2 N.C. Valve

2 N.C. Valve

2 20%

3 3°C (6°F)

2 20%

3 Supply

3 Heat / 2-10 V

3 N.O. Valve

3 N.O. Valve

3 30%

4 4°C (8°F)

3 30%

4 Auto changeover

4 Mech. relay

4 Mech. relay

4 40%

5 5°C (10°F)

4 40%

5 Limited cooling

5 SSR 3-32 V

5 Contact

5 50%

6 6°C (12°F)

5 50%

6 SCR 0-10 V

6 60%

7 7°C (14°F)

7 Act. 0-10 V

7 70%

8 8°C (16°F)

8 Act. / 2-10 V

8 80%

9 9°C (18°F)

9 90%

a.

If Output 2 type is set to 0-4, set the SW6 switch to Triac. If the output type is set to 5-8, set the switch to Analog (see section 4.7).

1F2T model

Application

(section 4.2)

Default mode

(section 4.3.1)

Output 2 type

a

(section 4.4)

Output 3 type

(section 4.5)

Output 3

activation

(section 4.5)

NSB value

(section 5.6)

Output 1

min. opening

(section 4.3.2)

Output 1

opening time

(section 4.3.3)

Maximum

setpoint

(section 4.6)

Minimum

setpoint

(section 4.6)

0 Internal sensor

0 Cool

0 Not used

0 Not used

0 100%

1 1°C (2°F)

0 0%

0 80

Can be set
between
35°C (95°F)
and ’’min
setpoint + 1’’

Default
value is
35°C (95°F)

Can be set
between
10°C (50°F)
and ’’max
setpoint - 1’’

Default
value is
10°C (50°F)

1 Room

1 Heat

1 SSR 24 VAC

1 SSR 24 VAC

1 10%

2 2°C (4°F)

1 10%

1 90

2 Return

2 N.C. Valve

2 N.C. Valve

2 20%

3 3°C (6°F)

2 20%

2 100

3 Supply

3 N.O. Valve

3 N.O. Valve

3 30%

4 4°C (8°F)

3 30%

3 110

4 Auto changeover

4 Mech. relay

4 Mech. relay

4 40%

5 5°C (10°F)

4 40%

4 120

5 Limited cooling

5 SSR 3-32 V

5 Contact

5 50%

6 6°C (12°F)

5 50%

5 130

6 SCR 0-10 V

6 60%

7 7°C (14°F)

6 140

7 Act. 0-10 V

7 70%

8 8°C (16°F)

7 150

8 Act. / 2-10 V

8 80%

9 9°C (18°F)

8 160

9 90%

a.

If Output 2 type is set to 0-4, set the SW6 switch to Triac. If the output type is set to 5-8, set the switch to Analog (see section 4.7).

n

Remove the thermostat from its base and
set the SW2 switch to MENU.

o

Reinstall the thermostat. The thermostat is
now in configuration mode. The first digit
flashes to indicate that the first item of the
menu can now be modified.

p

To modify the setting, use the up/down
arrows. Refer to the adjacent tables.

q

Press Override to save the new setting and
go to the next item.

r

Repeat steps 3 and 4 for remaining items.

s

When the configuration is done, set the
SW2 switch back to NORMAL.

NOTE: Factory settings are
inside the shaded cells.