Unit connectors – Axis Communications 262+ User Manual

Page 9

Advertising
background image

AXIS 262+ Installation Guide

Page 9

ENGLISH ENGLISH

Unit Connectors

RS-232 connector - For the connection of a UPS (Uninterruptible Power Supply) unit. For
approved models, see the AXIS 262+ User’s Manual.

Network connector- RJ-45 Ethernet connector. Using shielded cables is recommended.

I/O terminal connector - The 9-pin I/O terminal connector provides the interface to four
digital outputs, four digital photo-coupled inputs and Ground.

Pin

Event

Function

State

Specifications

Notes

Alarm
input

1

Must not be
exposed to volt-
ages greater
than 5V DC

Connect to GND
to activate, or
leave floating
(or uncon-
nected) to deac-
tivate.

2
3
4

Output

5

Alarm record-
ing starts/
stops

If any of the
sources start or
stop alarm
recording, AXIS
262+ outputs
the status

High/
Low

Max load =
100mA
Max voltage =
24V DC
(to the transis-
tor)

Uses an open-
collector NPN
transistor with
the emitter con-
nected to the
GND pin. If used
with an exter-
nal relay, a
diode must be
connected in
parallel with the
load, for protec-
tion against
voltage tran-
sients.

6

Camera lost

If any of the
sources looses a
connection with
a camera, AXIS
262+ outputs
the status

High

7

Hard disk
error

If a hard disk
error occurs, it
outputs the sta-
tus

High

8

Hard disk full

If the hard disk
is full it outputs
the status

High

GND

9

Ground

Pin layouts