3 sound distortion, 4 sound level is low, Altinex policies – Altinex MT108-103 User Manual

Page 17: 1 limited warranty/return policies, 2 contact information, Multitasker

Advertising
background image

MULTITASKER

400-0162-003

16

Cause 2:

The card output is turned OFF.

Solution 1: Turn on the card output that is used.

See RS-232 accessible commands
in section 7. If no sound is present,
see Solution 2.

Solution 2: If there is still no sound, see

Cause 3.

Cause 3:

Cable connections to the
destination are incorrect.

Solution:

Make sure the cables are connected
properly. Also, ensure that the
continuity and wiring are good. If
there is still no sound present, see
Cause 4.

Cause 4:

The destination amplifier has a
problem.

Solution 1: Make sure that

the destination

amplifier is powered. If there is still
no sound, see Solution 2

Solution 2: Set the volume of the destination

amplifier to a reasonable level. If
there is still no sound, call ALTINEX
at (714) 990-2300.

8.3 SOUND DISTORTION

Cause 1:

The source level is above 1V p-p.

Solution:

Make sure that the source level is
below 1 Vp-p. If the sound is still
distorted, see Cause 2.

Cause 2:

The destination amplifier provides
excessive amplification.

Solution 1: Make sure that the source signal

level is high enough so that the
destination amplifier does not have
to provide excessive amplification
and thereby distort the signal. If
there is still sound distortion, call
ALTINEX at (714) 990-2300.

8.4 SOUND LEVEL IS LOW

Cause 1:

The volume levels are
inappropriate.

Solution 1: Turn up the source volume. If sound

level is still low, see Solution 2.

Solution 2: Turn up the destination amplifier

volume. If the sound level is still low,
see Cause 2.

Cause 2

Poor signal transmission.

Solution:

Check the cables for continuity and
make sure that connections are
wired properly to verify that there is
good signal transmission.

Note:

Test the system by removing the
MT108-103 card from between the
source and the destination amplifier.
If problem persists, call ALTINEX at
(714)-990-2300.

ALTINEX POLICIES

9

9.1 LIMITED WARRANTY/RETURN POLICIES

Please see the ALTINEX website at

www.altinex.com

for details on warranty and

return policies.

9.2 CONTACT INFORMATION

ALTINEX, Inc.

592 Apollo Street

Brea, CA 92821 USA

TEL: 714 990-2300

TOLL FREE: 1-800-ALTINEX

WEB:

www.altinex.com

E-MAIL:

[email protected]

Advertising