Configuring remote alert settings, Configuring remote alert recipients – Lenovo ThinkServer TD200 User Manual

Page 30

Advertising
background image

5.

In the Lockout period after 5 login failures field, specify how long, in minutes,
the IMM prohibits remote login attempts if more than five sequential failures to
log in remotely are detected. The lockout of one user does not prevent other
users from logging in.

6.

In the Web inactivity session timeout field, specify how long, in minutes, the
IMM waits before it disconnects an inactive Web session. Select No timeout to
disable this feature. Select User picks timeout if the user will select the timeout
period during the login process.

7.

(Optional) In the Account security level area, select a password security level.
The Legacy security settings and High security settings set the default values
as indicated in the requirement list.

8.

To customize the security setting, select Custom security settings to view and
change the account security management configuration.

User login password required

Use this field to indicate whether a login ID with no password is
allowed.

Number of previous passwords that cannot be used

Use this field to indicate the number of previous passwords that cannot
be reused. Up to five previous passwords can be compared. Select 0 to
allow the reuse of all previous passwords.

Maximum Password Age

Use this field to indicate the maximum password age that is allowed
before the password must be changed. Values of 0 - 365 days are
supported. Select 0 to disable the password expiration checking.

9.

Click Save.

Configuring remote alert settings

You can configure remote alert recipients, the number of alert attempts, incidents
that trigger remote alerts, and local alerts from the Alerts link on the navigation
pane.

After you configure a remote alert recipient, the IMM sends an alert to that
recipient through a network connection when any event selected from the
Monitored Alerts group occurs. The alert contains information about the nature of
the event, the time and date of the event, and the name of the system that
generated the alert.

Note:

If the SNMP Agent or SNMP Traps fields are not set to Enabled, no SNMP
traps are sent. For information about these fields, see “Configuring SNMP”
on page 31.

Configuring remote alert recipients

You can define up to 12 unique remote alert recipients. Each link for an alert
recipient is labeled with the recipient name and alert status.

Note:

If you have not configured an alert recipient profile, the profile does not
appear in the remote alert recipients list.

To configure a remote alert recipient, complete the following steps:
1.

Log in to the IMM for which you want to configure remote alert settings. For
more information, see Chapter 2, “Opening and using the IMM Web interface,”
on page 9.

24

Integrated Management Module: User Guide