Power

AC power ingress

240 VAC, 20 Amps, single phase

Battery backup options
extended
glitch

120 minutes
5 minutes

-48 volts
@25 degrees C (degrees F)
for four bands

RAN box power use

2700 Watts Max.
16 Amps Max.

cPCI rack power

-48 VDC

Optical

Fiber cable ingress

Nylon connector accommodates
cable diameters in range 0.38-
0.50 inches (0.97-1.27 cm).

For larger cable sizes, refer to the
note in .

Fiber type

Corning SMF-28 or equivalent

Optical connectors

LC

Standard on SFP transceivers

Insertion loss

0.2 dB Typical, 0.4 dB Max.

Number of fibers required

1-4 fiber runs per RAN

Fiber configuration

Star (point to point) or ring

Ran ring limited to 3 SIFs

Fiber data link protocol

OC-48

Wavelengths per fiber
with WDM option
with CWDM option

1 (1310 nm)
2 (1310/1550)
8 (1470-1610)

Without WDM/CWDM option

20 nm increments (ITU-GRID)

Optical transceiver type

SFP

Dual LC connector

Optical Tx power

-3 dBm Max, -10 dBm Min.

Finistar FTRJ-1320-1
(or equivalent)

Optical Rx sensitivity

-22 dBm Typical, -18 dBm Max.

Optical link margin

2 dB

Estimated

Optical link loss

6 dB

Estimated

Optical Rx saturation level

-3 dBm

Min. Max. operational power

Optical Rx damage level

-3 dBm

Min. Max survivable power

Optical safety class

1

ANSI Z 136.2

RF

Tuning frequency
PCS band
Cellular band
SMR 800 band
SMR 900 band

Receive Path
1850-1910 MHz
824-849 MHz
806-824 MHz
896-901 MHz

Transmit Path
1930-1990 MHz
869-894 MHz
851-869 MHz
935-940 MHz

Instantaneous bandwidth

15 MHz

Table 3. NXD RAN Specifications

ITEM

SPECIFICATION

COMMENT