F4 adm – ATEN CS-1708 User Manual

Page 31

Advertising
background image

4. OSD Operation

23

F4 ADM

F4 is an Administrator only function. It allows the Administrator to configure
and control the overall operation of the OSD. To change a setting double click
it; or use the Up and Down Arrow Keys to move the highlight bar to it then
press [Enter].

After you select an item, a submenu with further choices for you to select from
appears. Double click the choice you want, or move the Highlight Bar to it then
press [Enter]. An icon appears before the selected choice so that you know
which one it is. The settings are explained in the following table:

(Continues on next page.)

Setting

Function

SET USERNAME
AND
PASSWORD

This function is used to set Usernames and Passwords for the
Administrator and Users:

1. Usernames and Passwords for one Administrator and four

users can be set.

2. After you select one of the User fields or the Administrator field,

a screen that allows you to key in a Username and Password
appears. The Username and Password may be up to 12
characters long, and can consist of any combination of letters
and numbers (A - Z, 0 - 9).

3. For each individual, key in the Username and Password, then

press [Enter].

4. To modify or delete a previous Username and/or Password,

use the backspace key to erase individual letters or numbers.

SET LOGOUT
TIMEOUT

If there is no input from the console for the amount of time set with
this function, the Operator is automatically logged out. A login is
necessary before the console can be used again.

This enables other Operators to gain access to the computers
when the original Operator is no longer accessing them, but has
forgotten to log out. To set the timeout value, key in a number from
1 - 180 minutes, then press [Enter]. If the number is 0 [zero], this
function is disabled. Default is 0 (disabled).

cs1708-1716.book Page 23 Thursday, July 19, 2007 3:06 PM

Advertising