Quality (q), Attention – ATS Handheld Inductive Loop Tester HILT 9000 User Manual

Page 7

Advertising
background image

6

www.atsi-tester.com

The LOOP test can measure a maxi-
mum

Q of 15. If Q is greater than 15

the tester displays

Q>15. To measure

the actual value, press the

Q button on

the keypad to run a separate

Q test.

The default frequency at which the
LOOP and

Q tests run is 50 KHz. It can

be changed to any value within the
range from 20 KHz to 80 KHz with 1
KHz increment.

Quality (Q)

ATTENTION

• Disconnect the detector from the loop before running

this test.

• DO NOT switch to a different test while the measure-

ments are being generated for the current test. Only
after the results of the current test are displayed can
a different test be performed.

Connect the test leads to the loop. This test requires several
seconds to run during which the tester will measure

Q at

some arbitrary frequency and calculate

Q for a user-selected

frequency. If a user-selected frequency is not entered prior to
pressing

Q, the default 50KHz setting

will be used. Refer to the Set
Frequency
section on page 7 for
full instructions to enter a different
frequency.

Both

Q results will be presented on the

display as shown in Figure 4. The
calculated value is shown on the
second line and indicated with an *.

R=12.3

Q=12.1

L=89.2µH

50KHz

Figure 3

Q=12.1

@40.5KHz

*

Q=14.9 @50.0KHz

Figure 4