Additional Protection LD2: As LD3, but in addition
Smoke or Heat Alarms in all rooms or areas that
present a high fire risk to occupants.

Heat Alarms located in:

(Heat Alarms must be within 5.3m of potential fire
sources)

each Kitchen

Smoke or Heat Alarms located in:

each Living room (i.e. most frequently used
daytime room)

Smoke Alarms located:

on each storey
every 7.5 m of hallways and escape routes
within 3m of all bedroom doors

(apart from toilets & bathrooms )

for new or materially altered dwellings or existing dwellings

with poor structural fire precautions

ADDITIONAL PROTECTION

LD2

Multi Storey Dwelling LD2

Living
Room

Bedroom

Bathroom

Kitchen

Bedroom

Shower

Garage

Bedroom

Bedroom

Bedroom

Kitchen / Dining Room

Living Room

Bathroom

Single Storey Dwelling LD2

Heat Alarm

do not fit alarm

Ionisation or Optical
Smoke Alarm

Optical Smoke Alarm

6