Aprilaire 8336 User Manual

Page 14

Advertising
background image

14

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R

Y

O

G

E

W1

L

C

T

LENNOX LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX

CB19 HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [COOLING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

V-VR

M

R

F

E

Y

X

LENNOX LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX

HP19 AND HP20 HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [COOLING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

24 VAC, COMMON