Engine and controller specifications 131 – Konica Minolta MAGICOLOR 2300 User Manual
Page 139
Engine and Controller Specifications
131
Environmental
Acoustic noise
data
Printing: Less than 54 dB (A)
Standby: Less than 39 dB (A)
Noise
Declaration for
Germany
Maschinenlärminformationsverordnung 3. FSGV,
18.01.1991: Der höchste Schalldruckpegel beträgt
70 dB (A) oder weniger gemäß EN 27779.
Relative
humidity
Operating: 15–85% RH (noncondensing)
Transportation/Storage: 30–85% RH (noncondensing)
Humidity Gradient: 20% per hour or less
Temperature
range
Operating: 50–95°F (10–35°C)
Transportation/Storage: 32–95°F (0–35°C)
Temperature Gradient: 18°F (10°C) per hour or less
Altitude
Operating: 0–8,202’ (0–2,500 m)
Limit of Low Pressure: 74.1 kPa
Transportation/Storage: Air pressure: 74.0–101.3 kPa
Inclination
Operating: ±1° or less slant at any point around the
machine
80
60
40
70
50
30
20
0
10
10
20
30
25
35
Optimal Operating Range
Acceptable Operating Range
Ambi
en
t
H
um
id
it
y
(%
RH)
50
59
68
77
86
95
Cº
Fº
Ambient Temperature
90
15