Installation, Automatic and manual switching mode settings – AMX AV2SM User Manual

Page 7

Advertising
background image

Installation

3

AV2SM A/V Switcher

Installation

You can install the AV2SM on any flat surface that has unobstructed access to both the front and

rear panel connectors.

Automatic and Manual Switching Mode Settings

You can select the switching mode by setting two internal jumpers on the circuit card inside the

enclosure. You will need a Phillips screwdriver to open the enclosure. To set the switching mode:

1.

Discharge the static electricity from your body and screwdriver.

2.

Unplug all connectors from the front and rear panel of the AV2SM.

3.

Turn the enclosure upside down and remove the two Phillips-head screws.

4.

Pull the enclosure apart and turn the bottom half, containing the circuit card, right-side up.

5.

Choose the desired switching mode:

!

For automatic mode (FIG. 2), place the 2-pin jumper on the E1 connector pin’s one and

two. Repeat for the E2 connector.

!

For manual mode (FIG. 3), place the 2-pin jumper on the E1 connector pin’s 2 and 3.

Repeat for the E2 connector.

FIG. 2 Automatic mode settings

FIG. 3 Manual mode settings

AUTO

MAN.

2

E1

E2

E1

AUTO

MAN.

AUTO

MAN.

2

E1

E2

E1

AUTO

MAN.

Advertising