The water flow control can be fine tuned to help tightly control the specific characteristics of your
particular still, and can help regulate varying input water pressures. There are four different presets
that can be chosen for use during operation.

To change the water flow rate control, turn on the EB120, and press and release the Drain key on the
remote. The Temperature Display will flash and show one of four pressure settings; 1PS, 2PS, 3PS,
4PS.

Press the Drain key one or more times to cycle through the four choices. When you see the selection
you want, press the Enter key to confirm. The Temperature display will stop flashing and return to
displaying the temperature reading of the still.

Finally, you MUST now press the On/Off button and turn the EB120 off, then press the On/Off button
once more and turn the unit back on. These steps are required to store the new setting, and to prevent
accidental changing of the water flow rate to the still.




Chapter Five: Troubleshooting guide

Please note that we recommend all repairs are carried out be a suitably qualified person.

Trouble description Possible Cause

Solution(s)

When the boiler is
turned on there is
no display on
control panel.

Check:

1. Power supply
2. Transformer
3. Main circuit

board

4. Controller
5. Control cable or

port

1. Check power supply voltage.
2. If the indicator LED of power supply isn’t on,

then check transformer or power supply.

3. If the LED remains red, remove the controller

turn off, reinstall the controller, and restart.

4. Change circuit board
5. Check the control cable port and controller.

System appears to
be turned on, but
the boiler is not
heating.

Check:
1. Beer supply.
2. Beer pump

operation.

3. Water level probe
4. Main board
5. Ground wire of boiler

and circuit board

6. Heating control

board

7. Heating elements

(1) Indicator LED for beer level is red. Check beer

input supply

(2) Check the connection of water level probe.
(3) Check ground wire connection of circuit board

and boiler.

(4) Indicator LED for beer level is green. Check

circuit board

(5) Check if overheat switch is disconnected
(6) Check heating elements

EB120 is turned on, Check:

Possibly need to: