The terminal is suitable for wall thicknesses from 228mm
to 600mm cut size

Should the installation of the appliance be in an unusual
location or restricted space, special procedures may be
necessary.

Terminal Position
The minimum acceptable spacings from the terminal to
obstructions and ventilation openings are as shown in the
diagram.
Where the terminal is fitted within 600mm below plastic
guttering an aluminium shield 1500mm long should be
fitted to the underside and immediately beneath the
guttering or eaves.
Where the terminal is fitted within 450mm below eaves or
painted guttering an aluminium shield 750mm long should
be fitted to the underside and immediately beneath the
guttering or eaves.

Minimum siting dimensions for Balanced Flue terminals

Position

Minimum Spacing

mm

A

Directly below an openable window,
air vent, or an other ventilation opening

300

B

Below gutter, drain/soil pipe

300

C

Below eaves

300

D

Below a balcony or car port roof

600

E

From vertical drain pipes and soil pipes

300

F

From internal or external corners

600

G

Above adjacent ground or balcony level

300

H

From surface facing the terminal

600

I

Facing terminals

600

J

From opening (door/window)
in car port into dwelling

1200

K

Vertical from a terminal

1500

L

Horizontally from a terminal

300

Terminal Protection
A terminal guard is supplied with the cooker and must be
fitted if flue termination is less than 2 metres above
ground level, or subject to damage.
When fitted, it must be positioned to provide a minimum
of 50mm clearance from any part of the terminal and be
central over the terminal.