Commissioning – Aga Ranges GEB User Manual

Page 6

Advertising
background image

LIGHTING THE BURNER - Fig. 2

CAUTION: NO SMOKING OR NAKED LIGHTS

Open the outer burner door to expose the gas control
combination valve.

CAUTION: BEFORE LIGHTING: ENSURE THAT THE
GAS VALVE CONTROL KNOB 2 IS SET IN THE OFF
POSITION (SEE FIG. A) AND COMBUSTION
DISCHARGE SAFETY DEVICE BUTTON IS
DEPRESSED.

1. Turn off union gas cock 1. Test the gas installation

from the meter cock for soundness and purge.

2. Turn on gas supply to cooker and open gas cock 1.

3. Turn the gas valve control knob 2 anti-clockwise to

the position (see Fig. B.). Press down and hold the
knob in the position while depressing the piezo ignitor
3 several times until the pilot has lit. This can be
observed through the viewing window 4.

4. When the pilot has lit continue to hold the gas valve

control knob for approximately 30 seconds. If it goes
out, wait 3 minutes and repeat the procedure holding
for a little longer.

5. With the pilot flame established, release the gas valve

control knob 2 gradually and rotate anti-clockwise to
its low fire position. Where upon the main burner will
automatically light. Leave in the low fire position for at
least 30 minutes.

NOTE: ANY ATTEMPT TO ROTATE THE CONTROL
KNOB BEFORE RELEASE MAY RESULT IN
DAMAGE.

6. After 30 minutes rotate the control knob further anti-

clockwise to the mid-position of the green band for
normal running (see Fig. D).

6

COMMISSIONING

OFF

ON

DESN 510252 ‘A’

FIG A

OFF

IGNITION

WHITE BLOCK

LOW FIRE

GREEN BAND

NORMAL RUNNING

FIG B

FIG C

FIG D

6

5

Advertising
This manual is related to the following products:

GCB, GE