1

2.2 GHz with Option 4, DDC.

2

For 50 and 65 GHz units, overshoot >40 GHz is 20% typical at rated power.

3

Period must be longer than the sum of delay and width by 5 clock cycles
minimum.

* Typical

10 to

<31.25 MHz

400 ns*

33%*

40 ns*

±70 mV*

(Opt. 4)

31.25 to

<125 MHz

90 ns*

22%*

12 ns*

±130 mV*

(Opt. 4)

125 to

<500 MHz

33 ns*

11%*

12 ns*

±70 mV*

(Opt. 4)

500 to

<2200 MHz

15 ns

10%

12 ns*

±15 mV*

(Opt. 4)

10 to

15 ns

<1000 MHz

10 ns*

10%

8 ns*

±15 mV*

(Opt. 5)

1 to

10 ns

<2 GHz

5 ns*

10%

8 ns*

±15 mV*

(Opt. 5)

2 to

10 ns

65 GHz

5 ns*

10%

2

8 ns*

±10 mV*

Frequency

Range

Rise & Fall

Time

(10% to 90%)

Overshoot

Pulse Width

Compression

Video

Feedthrough

Amplitude Modulation (Option 14)

All amplitude modulation specifications apply at 50% depth, 1 kHz
rate, with RF level set 6 dB below maximum specified leveled
output power, unless otherwise noted. Amplitude Modulation is not
available <10 MHz with Option 22.

AM Depth (typical):

0-90% linear; 20 dB log

AM Bandwidth (3 dB):

DC to 50 kHz minimum
DC to 100 kHz typical

Flatness (DC to 10 kHz rates):

±0.3 dB

Accuracy:

±5%

Distortion:

<5% typical

Incidental Phase Modulation (30% depth, 10 kHz rate):

<0.2 radians typical

External AM Input:

Log AM or Linear AM input, rear-panel BNC,

50

input impedance. For internal modulation, add LF Generator

Option 23.

Sensitivity:

Log AM: Continuously variable from 0 dB per volt to
25 dB per volt.
Linear AM: Continuously variable from 0% per volt
to 100% per volt.

Maximum Input:

±1V

LF Generator (Option 23)

Two internal waveform generators are added, one providing
a frequency or phase modulating signal and the other an amplitude
modulating signal. This Low Frequency (LF) Generator option can
only be ordered in combination with either FM/

Φ

M

or AM options,

12 and 14 respectively.

Waveforms:

Sinusoid, square-wave, triangle, positive ramp,

negative ramp, Gaussian noise, uniform noise. (Check Option 10
for User-Defined)

Rate:

0.1 Hz to 1 MHz sinusoidal
0.1 Hz to 100 kHz square-wave, triangle, ramps

Resolution:

0.1 Hz

Accuracy:

Same as instrument timebase

Output:

Two BNC connectors on the rear panel, FM/

Φ

M OUT and

AM OUT

External Input:

Rear-panel BNC. For internal modulation, add Pulse

Generator Option 24.

Drive Level:

TTL compatible input

Input Logic:

Positive-true or negative-true, selectable from

modulation menu.

Pulse Generator (Option 24)

Modes:

Free-run, triggered, gated, delayed, singlet, doublet, triplet,

quadruplet.

Accuracy:

10 ns (5 ns typical)

Inputs/Outputs:

Video pulse and sync out, rear-panel

BNC connectors

Pulse Generator option is not available without Pulse Modulation
Option 13.

Pulse Width

25 ns to 419 ms

100 ns to 1.6 s

Pulse Period

3

250 ns to 419 ms

600 ns to 1.6s

Variable Delay

Singlet

0 to 419 ms

0 to 1.6 s

Doublet

100 ns to 419 ms

300 ns to 1.6 s

Triplet

100 ns to 419 ms

300 ns to 1.6 s

Quadruplet

100 ns to 419 ms

300 ns to 1.6 s

Resolution

25 ns

100 ns

Parameter

Selectable Clock Rate

40 MHz

10 MHz

External Pulse Modulation (Option 13)

Pulse modulation specifications apply at maximum rated power,
unless otherwise noted. Pulse modulation is not available <10 MHz
with Option 22.

On/Off Ratio:

>80 dB

Minimum Leveled Pulse Width:

100 ns,

2 GHz

1

1 µs, <2 GHz

1

Minimum Unleveled Pulse Width:

<10 ns

Level Accuracy Relative to CW (100 Hz to 1 MHz PRF):

±0.5 dB,

1 µs pulse width

±1.0 dB, <1 µs pulse width

Pulse Delay (typical):

50 ns in External Mode

PRF Range:

DC to 10 MHz, unleveled
100 Hz to 5 MHz, leveled

Advertising