Designer solutions – Altinex UT250-101 User Manual

Page 19

Advertising
background image

DESIGNER SOLUTIONS

400-0503-001

18

20. [...S]

This command saves the configuration
command being sent in memory. Send the
command [I1O*S] to switch IN 1 to all outputs
and save the setting. After power-up or [CLR],
IN 1 will be connected to all outputs.

21. [AFB]

This command enables/disables the command
acknowledgement feedback, “[ ]”, from the
UT250-101. This setting is automatically saved
to memory and can only be changed by sending
the [AFB] command a second time. Use this
command when sending a large number of
commands with no delays, or when repeatedly
sending commands with no delays.

Command Format: [AFBm]

m

= 1 for ON, 0 for OFF

Example:

Send 16 commands to the UT250-101 to
initialize the card. The required commands are
as follows:

[I1O1A],

[I2O1B],

etc.

Send the [AFB] command first, and then the
switching commands.

[AFB0],

[I1O1A],

[I2O1B],

etc.

[AFB1]

In the above example, the brackets, “[ ]”, will not
be displayed after each command is executed.

22. [SIDn]

This command sets the UT250-101 to a new
unit ID. When assigning multiple IDs to several
units, connect only one unit at a time to the
RS-232 bus.

Command Format: [SIDn]

n

= Unit ID (n = # from 1 to 9)

Example:

There are two UT250-101 units on the RS-232
bus, but they need to be controlled individually.
Connect only the first unit to the bus and then
send [SID1]. This unit is now U1. Disconnect the
first unit and connect the second unit. Now send
[SID2] to the second unit. The second unit is
now U2.

23. [RSI]

This command resets the unit ID to U0.

Command Format: [RSI]

Example:

Send the command [RSI] to reset unit ID U1
assigned above back to U0.