Troubleshooting guide, Designer solutions – Altinex UT250-101 User Manual

Page 20

Advertising
background image

DESIGNER SOLUTIONS

400-0503-001

19

7.4. SUMMARY OF COMMANDS

1)

[STATUS]

Display card status

2)

[CLR]

Reset card to defaults

3)

[VER]

Display firmware version

4)

[ONmX]

Turn ON single output

5)

[ON]

Turn ON all outputs

6)

[OFFmX]

Turn OFF single output

7)

[OFF]

Turn OFF all outputs

8)

[InOmX]

Connect to one output

9)

[InO*]

Connect to all outputs

10) [...P]

Sets the path, [SW] preload

11) [SW]

Switch preloaded outputs

12) [AUTO*]

Auto-switch: ON, all outputs

13) [AUTO0]

Auto-switch: OFF

14) [AUTO1]

Auto-switch: ON, Out #1

15) [AUTO2]

Auto-switch: ON, Out #2

16) [HELP]

Display available commands

17) [?]

Display system information

18) [STA1]

Auto-feedback on

19) [STA0]

Auto-feedback off

20) [...S]

Save current setting

21) [AFB]

Enable/disable “[ ]”

22) [SIDn]

Set all Card IDs

23) [RSI]

Reset Card IDs to defaults

TROUBLESHOOTING GUIDE

8

We have carefully tested and found no problems in
the supplied UT250-101; however, we would like to
offer suggestions for the following:

8.1 POWER LEDS ARE OFF

Cause 1:

The unit is not plugged in.

Solution:

Make sure the power adapter is
plugged into a working AC outlet
and that the adapter’s DC end is
plugged all the way into the
UT250-101. If both LEDs are still not
ON, see Cause 2.

Cause 2:

The unit has a problem.

Solution:

If one power LED is on, but the other
is not then the UT250-101 may have
a problem. Please call ALTINEX at
(714) 990-2300.

8.2 NO DISPLAY

Cause 1:

The source has a problem.

Solution:

Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.

Cause 2:

The output is not selected.

Solution:

Verify the connection status of the
UT250-101. (See RS-232 accessible
commands in Section 7.) If no
display is present, see Cause 3.

Cause 3:

Cable connections are incorrect.

Solution:

Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 4.

Cause 4:

The display has a problem.

Solution:

Make sure the display is powered
and turned on. If there is still no
display, please call ALTINEX at
(714) 990-2300.

Advertising