Electric Convection Oven - Manual Control • Pg. 7.

The oven must be installed by a qualified electrician.
This appliance must be branch circuit protected with
proper ampacities, in accordance with the wiring
diagram located in this manual or in the electrical
compartment of the oven. The oven must be
properly grounded in accordance with the National
Electrical Code and applicable local codes.

Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the “off” position.

Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by a
licensed electrician in accordance with applicable
local electrical codes.

Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven model.
For supply connections, locate the wire size posted
on the label located near the electric terminal block
behind the service panel or elsewhere listed in this
manual. Before attempting the electrical connection,
the rating plate should be checked to ensure that the
electrical characteristics of the appliance and the
electrical supply characteristics agree.

Installation of the wiring must be made in
accordance with U.L. 197 Commercial Electric
Cooking Appliance Standards, Local and/or
National Electrical Code, ANSI /NFPA 70-1990.

Service line entry is made through the rear of the
oven for connection to the terminal block. Remove
the service panel on the right side of the oven for
access to the terminal block.

The oven is wired at the factory for either single
phase or three phase service as indicated on the
original purchase order. Input voltage and phase
must match the voltage and phase of the oven.
Visually check all electrical connections.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

E L E C T R I C A L • A S C - 2 E

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

208 (

AGCY

)

1

60

10

24.0

5.0

240 (

AGCY

)

1

60

10

20.8

5.0

208 (

AGCY

)

3

60

12

13.8

5.0

240 (

AGCY

)

3

60

12

12.0

5.0

N O C O R D A N D P L U G

E L E C T R I C A L • A S C - 4 E

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

208 (

AGCY

)

1

60

6

50.0

10.4

240 (

AGCY

)

1

60

6

43.3

10.4

208 (

AGCY

)

3

60

8

28.8

10.4

240 (

AGCY

)

3

60

8

25.0

10.4

480 (

AGCY

)

3

60

8

12.5

10.4

N O C O R D A N D P L U G