12.7 Cleaning the inlet hose and the valve filter

1.

1

2

3

2.

3.

4.

45°

20°

12.8 Emergency drain

Because of a malfunction, the appliance

cannot drain the water.
If this occurs, do steps (1) through (9) of

'Cleaning the drain filter'. If necessary,

clean the pump.
When you drain the water with the

emergency drain procedure, you must

activate again the drain system:
1. When you drain the water with the

emergency drain procedure, you

must activate again the drain system:

Put 2 litres of water in the main wash

compartment of the detergent

dispenser.

2. Start the programme to drain the

water

12.9 Frost precautions

If the appliance is installed in an area

where the temperature can be less than

0° C, remove the remaining water from

the inlet hose and the drain pump.
1. Disconnect the mains plug from the

mains socket.

2. Close the water tap.

3. Put the two ends of the inlet hose in

a container and let the water flow out

of the hose.

4. Empty the drain pump. Refer to the

emergency drain procedure.

5. When the drain pump is empty,

install the inlet hose again.

WARNING!

Make sure that the

temperature is more than 0

°C before you use the

appliance again. The

manufacturer is not

responsible for damages

caused by low temperatures.