Fiber optic cable length limitations, Table 3. 10base-fl rdn media adapter power budget – Bay Technical Associates BayStack Fiber Media Adapter User Manual

Page 10

Advertising
background image

8

893-863-A

Fiber Optic Cable Length Limitations

The 10BASE-F standard permits you to use fiber optic cables up
to 2000 meters long. However, the fiber connection must meet
the following criteria:

Optical power budget (shown in Table 3)

Ethernet repeater rules

For more information about simple rules for Ethernet network
compliance, refer to

Using the BayStack 10BASE-T Hubs

.

The optical power budget is shown in Table 3. Power loss in the
link cannot exceed the value for the type of fiber optic cable you
are using.

Only in-line fiber-to-fiber connections (a connection between
two fibers terminated with fiber connectors, using a fiber-to-fiber
connector) count against the optical power budget. The loss in a
fiber connection at the ends of the link are included in the optical
power budget and does not count as an in-line connection.

Table 3. 10BASE-FL RDN Media Adapter Power Budget

Parameter

62.5/125

µ

m

50/125

µ

m

Transmitted power (average)

–20 dBm

–25.7 dBm

Receiver sensitivity (average)

–32.5 dBm

–32.5 dBm

Optical power budget

12.5 dB

6.8 dB

Advertising