Menu setting method, Rec menu – Olympus VN-405PC User Manual

Page 29

Advertising
background image

29

4

EN

Menu setting method

M

e

nu
set
ting
m

e

th

od

Rec Menu

Rec Level

Recording sensitivity is adjustable to meet
recording needs.

1

Select [Rec Level] from the menu

on the [Rec Menu].

[High]:

High recording sensitivity suitable for
conferences with many participants
and recording audio at a distance or
low volume.

[Low]:

Standard recording sensitivity
suitable for dictation.

Note

• When you would like to clearly record a

speaker’s voice, set [Rec Level] to [Low]
and hold recorder’s built-in microphone
close to the speaker’s mouth (5-10 cm).

Rec Mode

Besides stereo* and monaural recording,
you can also select recording with priority to
sound quality, and recording with priority to
recording time. Select the recording mode
appropriate to your needs.

* VN-406PC only

1

Select [Rec Mode] from the menu

on the [Rec Menu].

When [MP3]* is selected:

Stereo recording
[192kbps], [128kbps]
Monaural recording
[48kbps]

* VN-406PC only

When [WMA] is selected:

Monaural recording
[32kbps], [16kbps], [5kbps]

Notes

• To record a meeting and lecture clearly,

set other than [5kbps] in [Rec Mode].

For VN-406PC:
• If a recording is made in stereo modes

([192 kbps] or [128 kbps]), it will be a
monaural recording through the built-in
microphone, and the same audio will be
recorded to both Left channel (Lch) and
Right channel (Rch).

• When an external monaural microphone

is used while [Rec Mode] is set to a stereo
recording mode, audio will be recorded
to the L channel only.

Low Cut Filter

The recorder has a Low Cut Filter function to
minimize low-frequency sounds and record
voices more clearly.

1

Select [Low Cut Filter] from the

menu on the [Rec Menu].

[On]:

Enables the Low Cut Filter function.

[Off]:

Disables this function.

Advertising
This manual is related to the following products: