Operation 15 – Breckwell ECONOMY P22FSL User Manual

Page 15

Advertising
background image

a.

POWER SWITCH

When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will stay on for at least 10 and up to 15
minutes, depending on when Proof of Fire is reached. The fire should start in about 5 minutes.

The red light located above the Power button (in the Power box) will flash during the ignition start-up period. (See figure 22)

The Feed Rate Advance is inoperable during the ignition start period. When the red light continuously stays on the Feed Rate Advance
can be adjusted to achieve the desired heat output.


NOTE: If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

b.

FUEL FEED SWITCH

When the “Fuel Feed” button is pushed and held down the stove will feed pellets continuously into the burnpot.

While the stove’s auger system is feeding pellets the amber light (in the “Fuel Feed” box) will be on. (See figure 22)


CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT COULD SMOTHER THE FIRE AND LEAD TO A
DANGEROUS SITUATION.

c.

HIGH FAN SWITCH

The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this variable speed function. It will set the
room air blower speed to high at any feed rate setting.

When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.

When this button is pushed again the room air fan will return to its original setting based on the Feed Rate Advance setting.

If the “HIGH FAN” setting is used for extended periods of time it can shorten the life expectancy of the room air fan. Avoid use at this
setting for more than one hour at a time.


d.

RESET TRIM


Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Feed Rate Advance bar graph. This is usually a
one-time adjustment based on the fuel you are using.
The “RESET TRIM” button when adjusted will allow for 3 different feed rate
settings for the #1 feed setting only. To adjust simply push the “RESET TRIM” button while the stove is operating at setting “1” and watch
the bar graph.

When the “1” and “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting. (approx. 0.9 pounds per hour)

When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.

When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its “highest” setting.


NOTE:
When the stove is set on “1” the “reset trim” values will be shown on the Feed Rate Advance bar graph. For example if the Reset
Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will be illuminated on the bar graph.

e.

FEED RATE ADVANCE

This button when pushed will set the pellet feed rate, hence the heat output of your stove. The levels of heat output will incrementally
change on the bar graph starting from level “1” to “4”.


CAUTION: THE “4” SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR EXTENDED PERIODS, IT CAN SHORTEN
THE LIFE EXPECTANCY OF THE UNITS COMPONENTS. AVOID USE AT THIS SETTING FOR MORE THAN ONE HOUR AT A TIME.

OPENING DOOR


If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove shuts down
push the “Power” button to continue the operation of your stove.

ROOM AIR FAN


When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes
from start-up.

RE-STARTING A WARM STOVE


If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.


OPERATION