BLOWERS


DANGER: RISK OF ELECTRIC SHOCK.
DISCONNECT POWER BEFORE SERVICING
UNIT.

a.

Cleaning – Over a period of time, ashes or
dust may collect on the blades of both the
combustion blower and convection blower.
Periodically the blowers should be vacuumed
clean as these ashes can impede
performance. Creosote can also accumulate in
the combustion blower. This needs to be
brushed clean. The convection blower is
accessed by removing the stove’s left side
panel. The combustion blower can be
accessed by removing the stove’s right side
panel. The convection blower is on the left
(facing stove), and the combustion blower is
on the right.

NOTE: When cleaning, be careful not to dislodge
balancing clip on convection blower or to bend fan
blades. Some stove owners lightly spray an anti-
creosote chemical on the fire to help reduce
creosote formation within the stove.

b.

Oiling – Convection blower only. Manufacturer
suggests oiling every 6 months. Refer to figure
27 for lubrication points. Use SAE 20W motor
oil or turbine oil. Limit to one or two drops.




FIGURE 27