background image

Conveyor belt

doesn't move, or it

moves unevenly.

Unexpected speed

changes.

Blower motor(s) "jammed"

Blower motor(s) "stalled" (not running

when Main Switch ON)

If all previous tests verify power and

control to gearmotor, replace gearmotor.

4. Verifywire connectors from power

supply to gearmotor (2 wires

w/connectors). If power supply doesn't

5. Verify potentiomter connections to

gearmotor (3 wires w/connectors). If

speed doesn't change when knob is

turned, test with spare pot before replacing

original pot.

Remove source(s) of obstruction.

CAUTION: TURN OFF MAIN CIRCUIT
BREAKER BEFORE REACHING INTO
BLOWER WHEEL COMPARTMENT.
SERIOUS INJURY COULD RESULT
OTHERWISE!!

THE PROBLEM

THE CAUSE

THE SOLUTION

CAUTION: THE FOLLOWING TESTS 1-

5 ARE PERFORMED WITH LIVE POWER

WITH CONTROL BOX OPEN, OR REAR

MOTOR COVER REMOVED. THESE

TESTS TO BE PERFORMED ONLY BY

AN AUTHORIZED SERVICE AGENT.

No air or not

enough air coming

from blower(s)

(Continued)

Conveyor gearmotor failed

(Continued)

Turn Main Switch OFF for at least 30

seconds, then turn it ON again. This

resets speed controls. If this doesn’t help,

turn OFF Main Circuit Breaker for

, then turn it ON again.

1

Minute

19

Oven not hot

enough

Temperature control not working properly

CAUTION: THE FOLLOWING TESTS

ARE PERFORMED WITH LIVE POWER

WITH CONTROL BOX OPEN. THESE

TESTS TO BE PERFORMED ONLY BY

AN AUTHORIZED SERVICE AGENT.