Lcdi power cord and plug – Brada Appliances YPL3-08C User Manual

Page 5

Advertising
background image

5

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and

plug. The LCDI power cord and plug will shut off the supply source via electrical disconnect (circuit trip) if the

nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.

The cord will not be able to conduct power until the devise has been manually reset. This device provides

protection to reduce the risk of fire due to arcing faults in the power cord. The cord shields are not grounded

and they must be considered as shock hazards if exposed. The cord shield must not be connected to

ground or to any exposed metal.

To ensure if the plug is working properly, please follow the following instructions to test it:

1. Plug power cord into wall outlet.

2. Press TEST button. The circuit should trip, cutting power to the air conditioner.

3. Press RESET button for use.

DO NOT USE IF ABOVE TEST FAILS.

In the event the LCDI Plug of the power cord trips by itself, then first examine the

cord for any damage. If there is no damage to the cord, then press the RESET

Button. If the LCDI Plug trips again, then immediately unplug the power supply

cord and contact a professional technician or service center.

WARNING:

1. Do not use the TEST and RESET buttons as “ON” and “OFF” switches.

2. Do not press the TEST button while the air conditioner is operating

3. The cord and plug are designed for indoor use only.

4. Periodically examine the cord for any damage. If the shield gets exposed, immediately unplug the

power cord and do not use the unit.