Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
Connection between Hood and exterior
blower
:

1. Remove the wiring box cover (A). Remove

a knockout from the wiring box.

2. Feed 6" of power cable through the knock-

out opening and secure cable to the wiring
box with an appropriate connector.

3. Make electrical connections and connect

the wires (see instructions in the exterior
blower).

4. Replace wiring box cover and screws.

Make sure that wires are not pinched
between cover and box.

Electrical connections:
1. Remove the wiring box cover (B). Remove

a knockout from the wiring box.

2. Feed 6" of power cable through the knock-

out opening and secure cable to the wiring
box with an appropriate connector.

3. Make electrical connections. Connect

white to white, black to black and green to
green.

4. Replace wiring box cover and screws.

Make sure that wires are not pinched
between cover and box.