Troubleshooting guide, Internal wiring diagrams, Trouble – Broan VX12000C User Manual

Page 5: Possible cause, Possible remedy, Cont’d)

Advertising
background image

page 5

Trouble

3. Power unit fails to

stop when the
hose is removed.

4. Power unit shuts

off during normal
operation, lights on
unit, wall valve and
hose are all red.

5. On Broan VX6000C

& VX12000C units
only, all lights on
control panel flash
when unit is first
plugged in.

Possible Cause

3a. An electrical short has occurred somewhere

in the system.

4a. Debris pail full sensing has been activated.

5a. Low line voltage.

Possible Remedy

3a. A complete check of all wall inlets and power unit

low voltage control lead connections.
Contact your authorized Service Center.

4a. Empty debris pail as described in page 3.

5a. Contact your local Service Center

.

TROUBLESHOOTING GUIDE

(CONT’D)

INTERNAL WIRING DIAGRAMS

• VX3000C • VX6000C

AE0005A

WHITE

WHITE

BLACK

BLACK

GREEN

GREEN

120 VOLTS

MOTOR

CONTROL

YELLO

W

YELLO

W

THERMAL

PROTECTOR

CONTROL

BOARD

BLUE

BLUE

AE0027A

RED OR WHITE

RED OR WHITE

RED OR WHITE

BLACK

BLACK

BLACK

BLACK

BLUE

GREEN

GREEN

GREEN

GREEN

YELLO

W

YELLO

W

MOTOR

MOTOR

CONTROL

CONTROL

BOARD

THERMAL

PROTECTOR

240 VOLTS

BLUE

THERMAL

PROTECTOR

BLUE

BLUE

• VX12000C