Maintenance

Testing Your GenAlert

Testing programmed phone number.

Press and hold the star (*) key until you see the

red LED light up.
Release the star key.

GenAlert will call the programmed number and play

the prerecorded alarm message. Canceling the alarm

for this test is not required.
Testing GenAlert Alarm.
The alarm goes off when the generator fails to

run when it is needed. To simulate this failure the

generator needs to be running to see the fault, then

shuts down, followed by the GenAlert calling the

programed number.

Simulate a fault by turning the generator circuit

breaker to the off position. The generator should

shut down and display the fault.
The red LED will light up and GenAlert will then

call the programmed number and indicate an

alarm.

1.

2.

1.

2.

Test Failure
If the test fails, first try reprogramming the phone

number and repeat the test. If a test failure persists,

refer to Troubleshooting.

Battery Replacement

Replace the battery every year.
GenAlert does not notify for “low battery” conditions.

Remove battery when the unit is not in use.