To change injectors, Changing the nozzles of the burners on the cooktop – Neff T22S46N0 User Manual

Page 12

Advertising
background image

12

Converting the

cooktop from Nat.

Gas to Universal LPG

To change injectors

All work involved in installation, setting and adaptation to

a different gas type must be carried out by authorised

personnel from our Service Centre and must comply with

current regulations and the conditions laid down by the

local gas company.
Request change-over injectors from our customer service

deparment (refer injector chart below for sizes).

Before conversion the cooktop must be disconnected

from the electricity and gas valves must be turned to the

OFF position.

Changing the nozzles

of the burners on the

cooktop

- Remove the pan supports, burner covers and

diffusers.Fig. 7.

- Change the nozzles using the spanner provided by our

Service Centre (code 340847, for double and triple flame

burners code 340808), taking special care to ensure that

the nozzle does not fall when it is removed from the

burner or when fitted. Fig. 8.

Natural Gas

Universal LPG

Burner

Hourly Gas

Consumption

(MJ)

Injector

mark

Hourly Gas

Consumption

(MJ)

Injector

mark

(mm)

Auxiliary

3,60

90

3,50

50

Semi-rapid

6,50

118

6,00

67

Rapid

10,80

155

10,00

85

(60) Double

flame

12,00

160

11,00

91

(70) Double

flame (inner)

18,00

85

18,00

46

(70) Double

flame (outer)

140

71

Fig. 7

Advertising