PREPARE THE HOOD

NON - DUCTED CONFIGURATION, cont’d.

7. Carefully place the lower decorative flue

into the recessed area of the range hood

top. Fig. 7.

8. Carefully slide the upper decorative flue

down inside the lower flue.

Note: air vents must be up. Fig. 7.

9. Secure the recirculation plenum to the

upper flue with (4) flat head screws.

Fig. 10.

PLENUM

FIG. 10

4 FLAT

HEAD

SCREWS

UPPER

FLUE

INSTALL THE
HOOD

Note: at least two people

will be required to mount

the hood.

1. Raise the hood into its

mounting position.

2. Plug the power cord into

the electric wall

receptacle. Tuck excess

cord behind the flue.

3. Align the rectangular

opening on the back of

the hood with the wall-

mounting bracket. Gently

lower the hood until it securely engages

the bracket. Fig. 11.

4. Level the hood with 2 mounting screws

(3.9x9.5mm) and secure with (2) mounting

screws. Use drywall anchors provided if

wall studs or framing are not available.

Fig. 11.

5. Mount the plate of the electrical system

attaching it with three mounting screws

(3.9x9.5mm). Fig. 12.

6. Raise the upper flue until its holes align

with holes in the flue mounting bracket

(located on ceiling). Fig. 13.

7. Secure the flue with (2) mounting screws.

Fig. 13.

FIG. 11

3.9x9.5mm

MOUNTING SCREWS

FIG.13

MOUNTING

SCREWS

(4.8x38mm)

MOUNTING

SCREWS

(4.8x38mm)

RECTANGULAR

CUTOUT

WALL FRAMING

MOUNTING

BRACKET

MOUNTING

SCREWS

(3.9x9.5mm)

FIG.12

PLATE OF

THE

ELECTRICAL

SYSTEM

MOUNTING

SCREWS

(3.9x9.5mm)