Non-ducted recirculation filter installation, Maintenance – Broan BEST K7388 User Manual

Page 11

Advertising
background image

- 11 -

NON-DUCTED
RECIRCULATION FILTER
INSTALLATION

1. Purchase a non-ducted recirculation filter

(B03300488) from your dealer.

2. Install the filter by pressing the 2 tabs on

the filter down into the special housing

and rotating upward.

NON-DUCTED

RECIRCULATION

FILTER

CLAMP

TABS

MAINTENANCE

Proper maintenance of the Range Hood will

assure proper performance of the unit.

Grease Filters
The grease filters must be cleaned

approximately once every 30 hours of

operation (when the central segment on the

display goes on or starts blinking).
Use a warm detergent solution. Grease filters

are dishwasher safe.
Remove filter by pushing filter towards the

back of hood and rotating filter downward.

Non-ducted Recirculation Filter
The non-ducted recirculation filter should be

changed whenever the central segment of

the display starts blinking (i.e. every 120

hours of operation). To remove the filter press

inward on the clamp and rotate the filter

downward until the 2 tabs can be removed

from the housing.

Hood Cleaning
Stainless steel is one of the easiest materials

to keep clean. Occasional care will help preserve its fine appearance.
Cleaning tips:

Hot water with soap or detergent is all that is usually needed.

Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to

avoid water marks.

For discolorations or deposits that persist, use a non-scratching household cleanser

or stainless steel polishing powder with a little water and a soft cloth.

For stubborn cases, use a plastic scouring pad or soft bristle brush together with

cleaser and water. Rub lightly in direction of polishing lines or "grain" of the

stainless finish. Avoid using too much pressure which may mar the surface.

DO NOT allow deposits to remain for long periods of time.

DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere

to the surface causing rust.

DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to

remain in contact with stainless steel for extended periods. Many of these com-

pounds contain chemicals which may be harmful. Rinse with water after expo-

sure and wipe dry with a clean cloth.

Painted surfaces should be cleaned with warm water and mild detergent only.

GREASE