EXTERNAL RELAY Main control board outputs 12vdc to activate external relay.
The N.O. contact then closes to provide line voltage to the heater in HOT WATER
TANK.

EXTERNAL RELAY

ON NEXT OFF

INDEX MOTOR DUMP runs the pod holder back to the pod ejection position.
LOAD moves it out to the door open position. "B " indicates the assembly is
in home postion.

INDEX B MOTOR

DUMP NEXT LOAD

AL R

TEST OUTPUTS allows testing of load components by manually turning them
ON/OFF.

---PLACE A 10 OUNCE CUP UNDER DISPENSE AREA---

WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!

TEST OUTPUTS ?

NO YES

TOR

PROGRAM FUNCTIONS

DRIP TIME (A/B) (OFF/1-50 seconds)
Time between brew cycle and pod ejection.

BREWS TO EMPTY (OFF/15-25)
Set number of used pods in bin to turn on "EMPTY BIN" message.

ENABLE ENERGY SAVER
Choose to have the tank heaters turn off, or reduce the tank temp to (140° F)
or (60° C) once the "SET IDLE TIME" has expired. .5-50.0 hrs.

AIR PUMP POWER (1 Weakest - 4 Strongest )
Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce
as needed if splattering occurs.

BREW COUNTS
Retains the total number of brew cycles completed, not reset-able.

BREW COUNTS
Retains the total number of brew cycles completed, reset-able.

CALIBRATE FLOW
This function allows you to enter the actual fl ow rate of the sprayhead by dispens-
ing for one minute. The volume is then entered in ounces per minute. (Oz/M)

Place a 10 ounce or larger measuring cup under sprayhead and press one of
the brew switches.

After dispense fi nishes, read number of ounces and enter that amount into brewer
using the +/- switches, then press "DONE" to set the volume into memory.

AIR PUMP POWER 4

(-) DONE (+)

Enabl EnergySavr

NO DONE YES

BREWS TO EMPTY

(-) 25 (+)

DRIP T I M E A/B: 15

(-) DONE (+)

BREW COUNT ##

RESET NEXT

BREW COUNT ##

NO YES

CALIBRATE FLOW ?

NO YES

PRESS

BREW TO START

ENTER OZ 10.0

(-) DONE (+)

CONTINUED

SERVICE TOOLS allows testing of load components and switches.
It should only be used by trained technicians.

SERVICE TOOLS ?

NO YES

?