Connect wiring, Install housing & duct – Broan VENTILLATION FAN QTR100 User Manual

Page 3

Advertising
background image

Page 

MODEL qtr100

5. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use

proper UL approved connector to secure house wiring to

wiring plate. Connect wires as shown in wiring diagrams.

CONNECt WIrING

3. Attach

damper/duct
connector.

Snap damper /

duct connector

onto housing.

Make sure con-

nector is flush with

top of housing and

damper flap falls

closed.

4. Install 4-

inch round
ductwork.

Connect 4-inch

round ductwork

to damper / duct

connector. Run

ductwork to a

roof cap or wall

cap. Tape all

ductwork con-

nections to make

them secure and air tight.

INStALL HOUSING & DUCt

1. Bend

housing
tabs.

Use a pliers to

bend housing

tABS out to 90

0

.

2. Mount

housing to
joist.

Hold housing

in place so that

the housing

tabs contact the

bottom of the

joist. The hous-

ing mounts with

four (4) screws

or nails. Screw or

nail housing to joist through lowest holes in each mount-

ing flange, then through highest holes. NOTE: Mounting

to I-JOISt (shown) requires use of SPACErS (included)

between the highest hole of each mounting flange and the

I-joist.

SPACER

(use for mounting to I-Joist)

I-JOIST

TABS

Advertising