RS-232 Baud Rate Change - cont’d.

All baud rates are entered as hex numbers. To determine the decimal

divisor use the following formula. The decimal number must be converted to
hexadecimal before entering the number into byte 6 and 7. Baud rates faster
than 57,600 are not supported.

UART clock = 7,372,800 Hz

Decimal Divisor = Clock frequency (7,372,800)

Baud output x 16


If you want a baud rate output of 300 baud:

Decimal Divisor = 7,372,800

300

x

16


Decimal Divisor = 1536 = 600 hex

Baud

1=

00

Baud

2=

06



Programming a baud rate change to 300 baud, 1 stop bit, 8 bit data, no parity.

Table 13. Baud Rate Setup

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte
1

Byte
2

Nibble 2

Nibble 1

Nibble 2

Nibble 1

UB3

Baud 1

Baud 2

81

21

0010 0011

0000 0010

81

21

23 hex

02 hex

03 hex

00 hex

06 hex

Table 13 is set to produce a baud rate of 300, 1stop bit, an 8 bit data

word, and no parity.