12 1939STB4600

Manual

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445


RS-232 Baud Rate Change cont’d.

Bit 2 stop bit works in conjunction with bits 1 and bit 0.

Table 16. Stop Bit Setup

Bit 2

Word length (bits)

Stop bit length

0

5, 6, 7, 8

1*

1

5

1

6, 7, 8

2

* Setup default value.


Bits 1 and 0 set the word length.

Table 17. Word Length

Bit 1

Bit 2

Word length

0

0

5

0

1

6

1

0

7

1

1

8*

* Setup default value.