OPERATION

Controls

The hood is operated using the (5) push-
buttons located at eye-level, on the front edge
of the hood.
The light switch turns the halogen lights on
and off. The blower on-off / speed 1 switch
turns the blower on to its lowest running
speed. Turn the blower off by pressing this
switch a second time. The blower speed 2
switch turns the blower on to medium-low
running speed. Pressing this switch a second
time sets a timer which keeps the blower operating at this speed for 10 minutes.
The LED will blink during this time and the blower will shut off automatically.
The blower speed 3 and blower speed 4 switches operate the same as blower
speed 2 switch except: Blower speed 3 is medium-high and blower speed 4 is
high.

At the end of each working time of 30 hours, all the leds blink at the same time; this
indicates that the grease filter need to be cleaned.
Once the clean grease filters are on, push the “blower speed 2 switch” twice (or
else the “blower speed 3 switch” or the “blower speed 4 switch”) during the blink of
the LED, to make the count down start again.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.

WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.