Connect ductwork, Wiring – Best KER222 User Manual

Page 8

Advertising
background image

- 8 -

CONNECT DUCTWORK

1. Use mounting screws (4,8x38mm) and wall

anchors to secure flue mounting bracket

to the ceiling or wall as shown.

2. Use 8" round metal duct to connect the duct

collar on the hood to the ductwork above.

3. Use duct tape to make all joints secure and

air tight.

4. Adjust the decorative flue to the desired

lenght and tighten screw.

FLUE

MOUNTING

BRACKET

MOUNTING

SCREWS

(4,8x38mm)

WIRING

Note: This range hood must be properly

grounded. The unit should be installed by a

qualified electrician in accordance with all

applicable national and local electrical

codes.

1. Remove the wiring box cover. Remove a

knockout from the wiring box.

2. Secure the conduit to the wiring box through

a conduit connector.

3. Make electrical connections. Connect white

to white, black to black and green to green or bare wire.

4. Replace wiring box cover and screws. Make sure that wires are not pinched

between cover and box.

WIRING BOX COVER

DUCT

COLLAR

HEIGHT ADJUSTMENT SCREWS

DEPTH ADJUSTMENT

SCREWS

MOUNTING

SCREWS

(4,8x38mm)

WALL

FRAMING

MOUNTING

BRACKETS

RECTANGULAR

CUTOUTS

MOUNTING

SCREWS

(4,8x38mm)

4. Depth adjustment screws provide

horizontal adjustment.

5. Secure the hood with mounting screws

(4,8x38mm). Use drywall anchors,

provided, if wall studs or framing are not

available.

6. Replace electrical box.

Advertising