Fault

Remedial action

Possible cause

Ice is forming in the supply hose to

the ice maker.

The water pressure is too low.

Check water pressure. The water pressure must be

between 25 and 120 p.s.i. (1.72ć8.25 bar).

The freezer compartment temperature

is too low.

Check temperature of the freezer compartment.

If required increase the temperature.

Water is flowing out of the

appliance.

The water pipe in the appliance is

defective.

Call customer service immediately.

pp

è Close shutĆoff valve immediately.

The water pressure is too low.

The valve may leak if the water pressure is too low.

The water pressure must be between 25 and 120 p.s.i.

(1.72ć8.25 bar).

A wrong water valve has been

installed.

SelfĆtapping valves and 3/16 inch (4.76 mm) saddle

valves reduce the water pressure and may eventually

block the pipe.

The manufacturer is not liable for damage to

property due to an incorrect installation or water

connection.

Changing the

bulb

d

WARNING

d

To avoid electrical shock which

can cause severe personal injury

or death, disconnect power to

appliance before making repairs.

After making repairs, reconnect

power.

q Switch off the appliance with

the POWER button!

CAUTION

Never touch a halogen bulb with

bare fingers. When inserting

a glass halogen bulb, always hold

with a soft cloth.

We recommend that a service

technician changes the bulb.

Halogen bulbs above

Halogen bulb type:

20 W/12 V/bulb holder G4

q Release and remove the cover.
q Pull out the defective halogen

bulb.

q Insert a new halogen bulb.

Touch the halogen bulb with

a soft cloth only.

q Attach the cover to the clip and

lock into position.