Oven/griddle control (thermostat), Vari-flame™ . . . fivestar, Oven and griddle burners – Brown Stove Works 60 Range User Manual

Page 7: Flame height

Advertising
background image

FIG. 13

FIG. 12 VARI-FLAME™

CENTER SIMMER BURNER

FIG. 10 STANDARD BURNER

CONVERSION

LP GAS SETTING

Tighten orifice hoods for surface and
oven burners approximately two
complete turns and adjust air
shutters. The gas pressure regulator
must be set to the LP gas setting to
provide 10 inches water column
pressure.

NAT. GAS SETTING

Unscrew orifice hoods for surface
and oven burners approximately two
complete turns and adjust air
shutters. The gas pressure regulator
must be set to the NAT. setting to
provide 4 inches water column
pressure.

FIG. 9 PRESSURE REGULATOR

CONVERSION

Oven/Griddle Control
(Thermostat)

The oven pilot gas selector screw is
located on this control. To change
oven pilot gas setting: (A) Remove
oven control knob by pulling straight
out. The oven gas selector screw is
found in the lower left hand corner
indicating “LP” or “N”. (B) These
letters will appear upside down
reading “

N

” and “

LP

”. (C) Rotate the

adjustment screw tab to the proper
setting. See Figure 8.

LP

N

All ranges are equipped with a gas
pressure regulator for controlling and
maintaining a uniform gas pressure in
the gas manifold of the range. The
burner orifices are sized for the gas
pressure delivered by the regulator
supplied. The pressure regulator
must not be removed
. To convert the
regulator from one gas to another
remove convertor cap by inserting a
coin into slot in top an twisting, turn
cap over and re-install. See Fig. 9.

Standard top burners . . . Be sure
the shipping screws have been
removed from the burners
. The
correct positioning should place the
top of the burner head approximately
3/8” below the cooking surface. See
Fig. 11.

Top burners have LOW, MEDIUM,
and HIGH positions. Adjust gas and
air mixture in the HIGH position. To
adjust LOW turn knob to LOW,
remove knob and while holding the
valve stem in the LOW setting with a
pair of pliers turn the adjusting screw
until a flame of approximately

1

/

8

” is

obtained.

High flames on surface burners are
inefficient and unsafe. The flame
should always be adjusted so that it
is no larger than the bottom of the
pan.

Pilot is out when control dial
is “OFF.” Spark electrode is
directly above “CHUTE.”

Vari-Flame™ . . . FiveStar

Standard front burners are equipped
with a true center-simmer feature that
is factory set. The burner orifice hoods
are black for NAT. gas and brass for
LP. gas. If the range is to be converted
from NAT. gas to LP. or vice versa call
800-251-7224 for proper orifices and
instructions.

Oven and Griddle Burners

These burners are supplied gas by
automatic safety valves. The safety
valve orifice must be set for the gas
being used. See Figure 10. This valve
is located at the base of the oven
burner in the broiler compartment and
at the base of the griddle burner in the
burner box under the griddle assembly.

Flame Height

Improper flame height is inefficient
and unsafe. The flame on these burners
should be blue in color and
approximately 1

1

/

4

” in height. See

Figure 13.

FIG. 8 PILOT GAS SELECTOR KEY

FIG. 11 TOP BURNER LOCATION

NEVER USE THE OVEN FOR
STORAGE

7

Front View

Harper-Wyman

Regulator

1”

3 / 8

1 1/4” OVEN BURNER

FLAME HEIGHT

1 1/4” GRIDDLE BURNER
FLAME HEIGHT

BURNER PAN

LPG

NAT

Converter

Cap

Pointer

Oven pilot selector key
switches from LP to NAT
(vice versa).

Advertising
This manual is related to the following products: