Install the ductwork, Install the housing, Model 784 page 3 existing construction – Broan 784 User Manual

Page 3: New construction

Advertising
background image

MODEL 784

Page 3

EXISTING CONSTRUCTION

1. Choose the location for your

fan in the ceiling. For best

possibleperformance, use the

shortest possible duct run and

a minimum number of elbows.

2. In attic, position mounting

brackets against joist. Trace

outline of housing on ceiling

material.

3. Set housing aside and cut

ceiling opening slightly larger

than marked.

4. Place housing in opening so

that its bottom edge is flush

with finished ceiling. Nail to joist

through keyhole on both sides.
To ensure a noise-free

installation, drive another nail

through the top hole of each

mounting bracket.

5. Additional mounting holes

are provided for installations

where access from above is

inconvenient or not possible.

Nail or screw housing

directly to joists or framing.

INSTALL THE DUCTWORK

1. Snap the damper/duct connector onto housing. Make sure

that tabs on the connector lock into slots in housing. Top of

damper/duct connector should be flush with top of housing.

2. Connect 4” round duct to damper/duct connector and extend

duct to outside through a roof or wall cap. Check damper to

make sure that it opens freely. Tape all duct connections to

make them secure and air tight.

NEW CONSTRUCTION

1. Choose the location

for your fan in the ceil-

ing. For best possible

performance, use the

shortest possible duct

run and a minimum

number of elbows.

2. Position mounting

brackets against joist

so that bottom edge of

housing will be flush

with finished ceiling.

Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling

material: Holes in corners of housing are labeled with various

ceiling material thicknesses. Position housing so bottom edge

of joist is visible through a matched set of holes. The housing

is now in the proper position for that ceiling material thickness.

Additional positioning feature for 1/2” thick ceiling material:

Bend two tabs, on side of housing, 90° outward. Lift housing until

tabs contact underside of joist. Mark the keyhole slot on both

mounting brackets.

3. Set housing aside and drive

nails partially into joist at the

top of both keyhole marks.

4. Hang housing from nails and

pound nails tight. To ensure a

noise-free mount, pound another

nail through the top hole of each

mounting tab.

5/8

1

1-1/4

BOTTOM EDGE OF JOIST

ADDITIONAL MOUNTING

HOLES

FLUSH

INSTALL THE HOUSING

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW

2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTAL-

LATION, MOUNT THE VENTILATOR TO THE ADDITIONAL

FRAMING IN THE SAME MANNER. (Additional framing

must be a 2x6 (minimum height), at least 9-inches long.)

HOLES

TAB

Advertising