Appliance dimensions

Setting up

• Avoid positioning the appliance in direct sunlight or near cookers,

radiators and similar sources of heat.

• The floor on which the appliance stands should be horizontal

and level.Compensate for uneven floors with the adjustable feet.

Do not cover ventilation openings

or grille.

• Standard EN 378 specifies that the room in

which you install your appliance must have a

volume of 1 m

3

per 8 g of R 600a refrigerant

used in the appliance, so as to avoid the forma-

tion of inflammable gas/air mixtures in the room

where the appliance is located in the event of

a leak in the refrigerant circuit. The quantity of

refrigerant used in your appliance is indicated

on the type plate on the inside of the appliance.

• Always install the appliance directly against

the wall.

• Place the appliance in its final position

at the place of installation.

Extend the adjustable foot at the bottom

hinge bracket until it rests on the floor

and then make a further 90° turn.

Saving energy

- Always ensure good ventilation. Do not cover ventilation open-

ings or grille.

- Always keep fan slits clear.

- Avoid positioning the appliance in direct sunlight or near cookers,

radiators or similar sources of heat.

- The energy consumption depends on the installation conditions,

e.g. the ambient temperature.

- Keep the time the appliance is open to a minimum.
Accumulated dust increases the energy consumption:

- Once a year, dust the refrigerating unit together with the metal

grid of the heat exchanger at the back of the appliance.

Climate rating

The climate rating indicates the room

temperature at which the appliance may

be operated in order to achieve full refrig-

eration performance.

The climate rating is indicated on the

type plate.

The position of the type plate is shown in the section entitled

Description of the appliance.

Climate rating

Room temperature

SN

+10°C to +32°C

N

+16°C to +32°C

ST

+16°C to +38°C

T

+16°C to +43°C

SN-ST

+10°C to +38°C

SN-T

+10°C to +43°C

Do not operate the appliance outside the

specified room temperature range.

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type

plate. The position of the type plate is shown in the section entitled

Description of the appliance.

The socket must be properly earthed and protected by a fuse.

The tripping current of the fuse must be between 10 A and 16 A.

The socket must not be situated behind the appli-

ance and must be easily accessible.

Do not connect the appliance using an exten-

sion cable or extension socket.

Do not use stand-alone inverters (conversion

of direct current to alternating/three-phase

current) or energy-saving plugs. Risk of dam-

age to the electronic control system!