4insertion into a row of kitchen units, 5disposing of packaging, Putting into operation – Liebherr CNsl 3033 Comfort NoFrost User Manual

Page 6: 4 insertion into a row of kitchen units, 5 disposing of packaging

Advertising
background image

Fig. 4

u

Follow the order of the positions.

4.4 Insertion into a row of kitchen units

Fig. 5

(1) Stack cabinet

(3) Kitchen cabinet

(2) Appliance

(4) Wall

The appliance can be inserted into a row of kitchen units. To

match the appliance

Fig. 5 (2)

to the height of the row of units,

a suitable stack cabinet

Fig. 5 (1)

can be fitted above the appli-

ance.
When inserting the appliance into a row of kitchen units (max.

depth 580 mm), the appliance can be installed directly next to

the kitchen unit

Fig. 5 (3)

. The appliance door projects relative

to the front of the kitchen unit by 34 mm at the side and by

50 mm in the middle of the appliance. It can be opened and

closed perfectly as a result.
Important for the ventilation:

-

At the back of the stack cabinet there has to be a ventilation

duct of at least 50 mm depth throughout the width of the

stack cabinet.

-

The ventilation space under the ceiling has to be at least

300 cm

2

.

-

the larger the ventilation space, the more energy-saving the

appliance is in operation.

If the appliance is installed with the hinges next to a wall

Fig. 5 (4)

, the distance between appliance and wall has to be at

least 40 mm. This corresponds to the projection of the handle

when the door is open.

4.5 Disposing of packaging

WARNING

Danger of suffocation due to packing material and plastic film!

u

Do not allow children to play with packing material.

The packaging is made of recyclable materials:

-

corrugated board/cardboard

-

expanded polystyrene parts