Dual Homing Application

The Dual Homing function is used to prevent a connection loss between the

X-Ring group and the upper level/core switch. Assign a port in each X-ring

group to be the Dual Homing ports The Dual Homing function can only be

used when the X-Ring function is active. Each X-Ring group can have one

Dual Homing port. Note: The upper level switches must have RSTP

enabled.